BTU Calculator — What Size Air Conditioner Do I Need?
Enter your room size and get the BTUs you need — 20 BTU per square foot, adjusted for sun exposure, ceiling height, people and kitchens.
A 20×15 ft room needs a 6,000 BTU air conditioner — about 0.5 tons.
BTU calculator
Results update as you type. Your numbers are saved in the page link, so you can bookmark or share them.
This is a sizing estimate for a single room, not a whole-house load calculation (Manual J). If your total lands between standard sizes, round up — an undersized unit runs constantly and never catches up.
How the btu calculator works
This calculator tells you how many BTUs of cooling capacity a room needs, so you can buy an air conditioner that is neither undersized nor oversized. BTU stands for British Thermal Unit, and in air conditioning it measures how much heat the unit can remove from a room per hour. Room air conditioners and mini-splits are sold by BTU rating, and window units are also commonly labeled in tons — one ton equals 12,000 BTU.
The core of the calculation is simple: you need about 20 BTU per square foot of floor area for a standard room with an 8-foot ceiling. The calculator takes your room's length and width, multiplies them to get square footage, and multiplies that by 20 to get the base BTU load.
The math, step by step
base BTU = length (ft) × width (ft) × 20 × (ceiling height ÷ 8)sunny room: × 1.10 · shaded room: × 0.90
+ 600 BTU per person over 2 · kitchen: + 4,000 BTU
tons = BTU ÷ 12,000
- 20 BTU per sq ft: the standard rule of thumb for an 8 ft ceiling in a normally insulated room.
- Ceiling height: a 10 ft ceiling holds 25% more air than an 8 ft one, so the base scales by height ÷ 8.
- Sun: a sunny room gains about 10% more heat; a heavily shaded room loses about 10% of the load.
- People and kitchens: each person over two adds about 600 BTU of body heat; a kitchen adds about 4,000 BTU from cooking.
- Tons: one ton of cooling = 12,000 BTU per hour — a 0.5 ton unit is a 6,000 BTU window unit.
Each of the other inputs adjusts that base number, because real rooms are not all average:
- Sun exposure. A sunny room gains heat through the windows and walls, so it needs about 10% more capacity. A shaded room holds heat better and needs about 10% less. If the room gets direct sun for a good part of the day, choose sunny; if it is shaded by trees or rarely sees direct sun, choose shaded. - Ceiling height. The 20 BTU per square foot rule assumes an 8-foot ceiling. The calculator scales the base load by your ceiling height divided by 8, so a 10-foot ceiling raises the load by 25%. - People. Bodies give off heat. The base number already covers two occupants; each additional person adds 600 BTU. - Kitchen. Cooking appliances dump a lot of heat into a space, so if the room is a kitchen you add 4,000 BTU. - Insulation. Poor insulation lets heat in faster, adding 10% to the load. Good insulation cuts it by 10%.
Once all adjustments are applied, the calculator divides the total by 12,000 to express the result in tons.
Getting the size right matters in both directions. An undersized unit runs constantly on hot days and never quite cools the room. An oversized unit cools the air fast but shuts off before it has dehumidified properly, leaving the room cold and clammy. Sizing from square footage with the adjustments above is the standard way contractors handle it, and it works well for ordinary rooms. Note that this calculator is for individual rooms — sizing a whole-house central system involves ductwork, orientation and climate factors beyond this page.
Take the sunny 25×20 ft living room with 4 people. The floor area is 500 sq ft, so the base load is 500 × 20 = 10,000 BTU. The room is sunny, which adds 10%, bringing it to 11,000 BTU. With two more people than the standard of 2, you add 600 BTU per extra person, or 1,200 BTU total, which lands the room at 12,200 BTU — about 1.02 tons. Notice how each factor builds on the last: sun exposure and occupancy each push the number up independently, and only after all adjustments do you divide by 12,000 to get the tonnage. Now take the same 20×15 ft room used as a kitchen. The base is 6,000 BTU at average sun and an 8 ft ceiling, but kitchens carry a flat 4,000 BTU addition to account for heat from cooking appliances, giving 10,000 BTU, or about 0.83 tons. That is nearly double the base figure for the identical floor area, which is why the calculator treats kitchens as a separate condition rather than scaling by size alone. Once you have your result, resist the urge to round up generously. An oversized air conditioner cools the room quickly, satisfies the thermostat, and shuts off before it has run long enough to pull moisture out of the air. The result is short cycling: frequent starts and stops that wear out the compressor, waste energy on each startup, and leave the room cold but clammy. Undersizing has the opposite, more obvious problem — the unit runs constantly and never quite reaches the set temperature — but oversizing is the more common mistake because bigger seems safer. It is not. A unit matched to your calculated BTU load will run in longer, steadier cycles, dehumidify properly, and hold a more even temperature. If your result falls between two common sizes, such as between 0.5 and 1 ton in the guide below, choose the closer one rather than automatically stepping up.
Worked example: a 20 × 15 ft room
Here is the worked example from the calculator: a 20×15 ft room with an 8-foot ceiling, average sun, two people, no kitchen, and average insulation.
- Room area: 20 ft × 15 ft = 300 square feet.
- Base load: 300 sq ft × 20 BTU per sq ft = 6,000 BTU.
- Ceiling adjustment: the ceiling is 8 ft, so the multiplier is 8 ÷ 8 = 1, and the load stays 6,000 BTU.
- Sun adjustment: average sun means no change, so the load stays 6,000 BTU.
- People adjustment: two people are already covered by the base, so no change — 6,000 BTU.
- Kitchen adjustment: no kitchen, so no change — 6,000 BTU.
- Insulation adjustment: average insulation means no change — 6,000 BTU.
- Final result: 6,000 BTU, which is 6,000 ÷ 12,000 = 0.5 tons.
- Start with the room load from above: 6,000 BTU.
- Add the kitchen allowance: 6,000 + 4,000 = 10,000 BTU.
- Convert to tons: 10,000 ÷ 12,000 = 0.83 tons.
So the identical room needs a 6,000 BTU unit as a bedroom or living space, but 10,000 BTU as a kitchen. The kitchen heat from the stove, oven and refrigerator is what pushes the requirement up. In practice, that is the difference between a medium window unit and a larger one, so it pays to answer the kitchen question honestly in the calculator.
Quick reference tables
Speed sheetThese examples show how common room sizes translate into BTU requirements under typical conditions
These examples show how common room sizes translate into BTU requirements under typical conditions.
| Room | Condition | BTUs Needed | Tons |
|---|---|---|---|
| 12×12 ft bedroom | average sun, 8 ft | 2,880 BTU | 0.24 tons |
| 20×15 ft room | average sun, 8 ft | 6,000 BTU | 0.5 tons |
| 25×20 ft living room | sunny, 4 people | 12,200 BTU | 1.02 tons |
A quick guide to how tons relate to BTUs and room size.
| Tons | BTUs | Coverage |
|---|---|---|
| 0.5 ton | ≈ 6,000 BTU | up to ~300 sq ft |
| 1 ton | ≈ 12,000 BTU | up to ~600 sq ft |
| 1.5 tons | ≈ 18,000 BTU | up to ~900 sq ft |
| 2 tons | ≈ 24,000 BTU | up to ~1,200 sq ft |
What an air conditioner costs
The calculator gives you capacity, not price, but capacity is what drives cost. Air conditioners are priced and sold by size: a 6,000 BTU window unit (0.5 tons) sits at the small end, a 12,000 BTU unit (1 ton) is a mid-size room unit, and 18,000–24,000 BTU units (1.5–2 tons) move into mini-split territory, which costs more for the equipment and requires professional installation.
As national planning ranges checked November 2026, expect smaller window units to cost well under larger room units, and expect mini-split systems to cost meaningfully more than window units once installation is included. Running cost follows the same pattern: a properly sized unit cycles on and off normally, while an oversized unit short-cycles and an undersized one runs nonstop — both waste electricity.
Use the BTU figure to shop the right size class first, then compare prices within that size. Prices vary by brand, efficiency rating and retailer, so treat any figure you see as a planning number, not a quote, and confirm current pricing at the store before you buy.
Frequently asked questions
How many BTUs do I need per square foot?
The rule of thumb is 20 BTU per square foot of floor area for a room with an 8-foot ceiling. This calculator starts there, then adjusts for sun exposure, ceiling height, number of people, kitchen use and insulation.
What size air conditioner do I need for a 20×15 ft room?
A 20×15 ft room is 300 square feet, so at 20 BTU per square foot it needs a 6,000 BTU unit, which is 0.5 tons. That assumes an 8-foot ceiling, average sun, two people and no kitchen — the calculator adjusts if your room differs.
How do I convert BTUs to tons?
Divide BTUs by 12,000. So 6,000 BTU is 0.5 tons, 12,000 BTU is 1 ton, 18,000 BTU is 1.5 tons and 24,000 BTU is 2 tons.
Does ceiling height change the BTU requirement?
Yes. The 20 BTU per square foot rule assumes an 8-foot ceiling. The calculator scales the base load by your ceiling height divided by 8, so a taller ceiling increases the required BTUs.
How much extra capacity does a kitchen need?
Add 4,000 BTU if the room is a kitchen, because stoves, ovens and refrigerators add significant heat. In the worked example, a 20×15 ft room that needs 6,000 BTU normally needs 10,000 BTU (0.83 tons) as a kitchen.
How many BTUs do I add per person?
The base calculation already covers two people. Each person beyond that adds 600 BTU. So a living room with four people adds 1,200 BTU over the base.
What happens if I buy an air conditioner that is too big?
An oversized unit cools the air quickly and shuts off before it removes enough humidity, leaving the room cold and clammy. Short cycling also wastes electricity. Size to the calculated BTUs rather than buying bigger "to be safe."
Does sun exposure really matter for sizing?
Yes. A sunny room gains heat through windows and walls, so the calculator adds 10% to the base load. A shaded room needs 10% less. Pick sunny if the room gets direct sun much of the day, shaded if trees or buildings block it.
Assumptions and limitations
- Base cooling load is 20 BTU per square foot of floor area, which assumes a standard 8-foot ceiling and average conditions.
- Sunny rooms add 10% to the base load; shaded rooms subtract 10%.
- The base load covers two occupants; each additional person adds 600 BTU.
- Kitchens add a flat 4,000 BTU to cover heat from cooking appliances.
- Poor insulation adds 10% to the load; good insulation reduces it by 10%; average insulation means no change.
- One ton of cooling equals 12,000 BTU, and results apply to a single room, not a whole-house central system.
Sources
- U.S. Department of Energy — energy.gov — guidance on sizing room and whole-house air conditioners.
- Air-Conditioning, Heating, and Refrigeration Institute (AHRI) — ahri.org — certification standards and cooling capacity ratings.
- Lennox — lennox.com — manufacturer sizing guides and BTU/ton explanations.
- Home Depot — homedepot.com — retailer listings for window and portable AC units by BTU rating.
Last reviewed: November 20, 2026, by the YardMath Editorial Team. Formulas re-checked against manufacturer datasheets; national price ranges refreshed quarterly.