Insulation Calculator — Bags Needed by R-Value
Enter your area and target R-value and get the bags you need — coverage per bag comes from manufacturer charts, with thickness and cost included.
A 1,000 sq ft attic at R-30 needs 32 bags of insulation.
Insulation calculator
Results update as you type. Your numbers are saved in the page link, so you can bookmark or share them.
Bags always round up to whole bags. Coverage per bag comes from manufacturer charts for 15 in batts; blown-in coverage is similar at the same R-value. Check your local code for the minimum R-value.
How the insulation calculator works
This calculator tells you how many bags of insulation you need to hit a target R-value over a given area. You enter two things: the square footage of the space you're insulating (an attic floor, a wall, or a ceiling) and the R-value you're aiming for. You can also enter a price per bag if you want a cost estimate alongside the bag count.
Both inputs matter, and they matter in different ways. Area is straightforward — measure the length and width of the space and multiply. If your attic is 25 ft by 40 ft, that's 1,000 sq ft. Don't subtract for framing or obstructions unless the gaps are large; batts get cut around them and the offcuts don't stretch far.
The math, step by step
bags = area (sq ft) ÷ coverage per bag (round up)coverage per bag: R-13 → 88.75 sq ft · R-19 → 48.96 · R-30 → 31.25 · R-38 → 24.50
- R-value: resistance to heat flow — higher means better insulation. R-30 needs about 9.5 in of fiberglass; R-38 needs about 12 in.
- Coverage: one bag covers less area as the target R-value rises, because the same bag is spread thinner to hit a lower R-value or thicker for a higher one.
- Attic rule: measure the attic floor area, not the roof — insulation sits on the floor, and the roof slope does not add area.
- Existing insulation: if you are topping up, subtract the area already covered at your target R-value; this calculator sizes a full fresh install.
R-value is the one people get wrong. R-value measures resistance to heat flow, and it's not something you pick by feel — it's set by climate zone and local building code. A cold-zone attic might need R-49 or R-60, while a warm-zone one might only need R-30. Walls typically fall between R-13 and R-21. We cover the recommended ranges further down this page.
The formula itself is simple:
bags = ceil(area ÷ coverage per bag)
Coverage per bag is the key number, and it comes straight from manufacturer coverage charts. Every R-value has a different coverage per bag because higher R-values use denser or thicker material — you get less square footage per bag as you go up. For 15-in batts, the manufacturer charts give these figures: R-13 covers 88.75 sq ft per bag, R-19 covers 48.96, R-21 covers 42.80, R-30 covers 31.25, and R-38 covers 24.50.
The "ceil" part means we always round up to a whole bag. You can't buy two-thirds of a bag, and insulation isn't something you want to run short on mid-job. If the math says 31.4 bags, you buy 32.
Thickness comes along for the ride. Each R-value has a nominal installed thickness for these batts: R-13 is 3.5 in, R-19 is 6.25 in, R-21 is 5.5 in, R-30 is 9.5 in, and R-38 is 12 in. That matters for planning — an R-38 attic needs a foot of clearance, which affects whether you can fit it between framing, around recessed lights, and past attic hatches. Check your joist depth before committing.
Cost is the last output: bags × price per bag. The price field defaults to $55 per bag, which is a reasonable national planning range checked November 2026 for kraft-faced fiberglass batts, but local pricing varies. Swap in your local number and the cost updates.
One caution: coverage per bag differs between manufacturers and between batt and loose-fill products. The figures here follow the manufacturer charts for 15-in batts. If you're using loose-fill, blown cellulose, or a different product line, check that product's own chart — bag counts can shift meaningfully.
Choosing the right R-value starts with where the insulation goes. For attics, the recommended range runs from R-30 to R-60, with colder climate zones needing the higher end of that range — a home in a warm region can stop near R-30, while a home in a cold region should push toward R-60. Walls call for R-13 to R-21, which fits the standard stud cavity, and floors fall between R-13 and R-30 depending on how cold the space below them gets. These ranges come from US DOE climate zone recommendations, but they are only a starting point: your local building code sets the minimum R-value for each part of your house, and it overrides any general chart. Check your code requirements before you buy, because ordering for the wrong target means either paying for bags you did not need or failing inspection. Thickness is the other check that trips people up. Each R-value corresponds to a specific installed thickness for 15-in batts: R-13 measures 3.5 in, R-19 measures 6.25 in, R-21 measures 5.5 in, R-30 measures 9.5 in, and R-38 measures 12 in. Compare those numbers against your joist or stud depth before ordering. R-13 at 3.5 in fits a standard 2x4 wall cavity, and R-19 at 6.25 in fits a 2x6 cavity, but R-30 at 9.5 in and R-38 at 12 in will not fit under a standard joist deck without either raised attic baffles or a deeper framing bay. If you compress insulation to make it fit, you lose R-value — a batt rated R-38 squeezed into a 9.5-in space will not perform at R-38. In attics, this usually means insulating between the joists first and running perpendicular layers across them to reach the total target, which also covers the joists themselves, a common thermal leak. Measure your joist depth and cavity width, confirm your code minimum, then pick the R-value that fits both, and the calculator's bag count and thickness output will match what you actually install.
Worked example: a 1,000 sq ft attic at R-30
Here's the worked example for a 1,000 sq ft attic at R-30, using the default $55 per bag.
- Start with the area: 1,000 sq ft. That's the attic floor you're covering — say 25 ft × 40 ft.
- Target R-value: R-30. From the manufacturer coverage chart for 15-in batts, R-30 covers 31.25 sq ft per bag.
- Divide area by coverage per bag: 1,000 ÷ 31.25 = 32.
- Round up to whole bags: ceil(32) = 32 bags. The division lands on an even 32, so no rounding up is needed here — but the calculator always rounds up to be safe.
- Installed thickness at R-30 is 9.5 in. Plan your joist depth and clearances around that figure.
- Cost: 32 bags × $55 per bag = $1,760. That's a planning figure, not a quote — swap in your local bag price for a number that matches your market.
That's the whole job on paper: 32 bags, 9.5 in of thickness, roughly $1,760 at the default planning price.
Quick reference tables
Speed sheetThis table shows the bag count for a 1,000 sq ft area at each R-value, using the manufacturer coverage-per-bag figures for 15-in batts
This table shows the bag count for a 1,000 sq ft area at each R-value, using the manufacturer coverage-per-bag figures for 15-in batts.
| R-value | Bags for 1,000 sq ft |
|---|---|
| R-13 | 12 |
| R-19 | 21 |
| R-21 | 24 |
| R-30 | 32 |
| R-38 | 41 |
These are the US DOE-recommended R-value ranges by application. Your local code sets the minimum — check it before you buy.
| Application | Recommended R-value range |
|---|---|
| Attics | R-30–R-60 (colder zones higher) |
| Walls | R-13–R-21 |
| Floors | R-13–R-30 |
What insulation costs
The only cost figure this calculator produces is bags × price per bag. The default price is $55 per bag, a national planning range checked November 2026 for faced fiberglass batts. It is not a quote and it will not match every market — bag pricing moves with region, product line, and retailer.
Using the defaults, the worked example works out to 32 bags × $55 = $1,760 for a 1,000 sq ft attic at R-30. If your local price is higher or lower, enter it and the cost scales linearly — 32 bags at $48 is $1,536; at $62 it's $1,984.
A few practical notes. Bag price alone doesn't capture the whole job budget: you may also need a vapor barrier, tape, a utility knife and straightedge, and — for attics — boards for walkways and a light. Don't forget disposal of packaging.
Second, cheaper per-bag pricing isn't always cheaper per square foot. Because coverage per bag drops as R-value rises, a higher-R product can cost more per bag but similar per square foot of installed R-value. Compare price divided by coverage per bag, not just the sticker.
Third, when you price out a job, add a small buffer to your bag count for cuts around framing, fixtures, and hatches. Offcuts from batts are rarely reusable in useful sizes.
Treat every dollar figure here as a planning number. Get a local quote before you commit a budget.
Frequently asked questions
How many bags of insulation do I need for 1,000 sq ft at R-30?
32 bags. R-30 covers 31.25 sq ft per bag, and 1,000 ÷ 31.25 = 32 exactly.
How thick is R-30 insulation?
For the 15-in batts these charts cover, R-30 installs at 9.5 in nominal thickness. Check your joist depth before buying.
How much does it cost to insulate a 1,000 sq ft attic at R-30?
At the default planning price of $55 per bag, 32 bags × $55 = $1,760. That's a national planning range checked November 2026, not a quote — enter your local bag price for a better figure.
What R-value should I use for my attic?
US DOE guidance puts attics in the R-30–R-60 range, with colder climate zones at the higher end. Local code sets the minimum, so check it before ordering.
Why do higher R-values cover fewer square feet per bag?
Higher R-values use thicker, denser material. R-13 covers 88.75 sq ft per bag while R-38 covers only 24.50, so the same area takes more bags as you move up.
Are these bag counts valid for loose-fill insulation?
No. These figures follow the manufacturer coverage charts for 15-in batts. Loose-fill products have their own coverage charts, and bag counts can differ significantly.
What R-value do walls need?
The recommended range for walls is R-13–R-21. R-13 covers 88.75 sq ft per bag and R-21 covers 42.80, so a wall job at R-21 takes roughly twice the bags of the same wall at R-13.
Why does the calculator round the bag count up?
Bags are sold whole, and running short mid-job wastes time. The formula uses ceil(area ÷ coverage per bag), so 31.4 bags becomes 32.
Assumptions and limitations
- The area entered is the actual surface to be covered, measured in square feet, with no deduction for framing, fixtures, or small obstructions.
- Coverage per bag comes from manufacturer charts for 15-in batts: R-13 → 88.75 sq ft; R-19 → 48.96; R-21 → 42.80; R-30 → 31.25; R-38 → 24.50.
- Bag counts are always rounded up to the next whole bag, since partial bags are not sold.
- Installed thickness follows the nominal figures for these batts: R-13 → 3.5 in; R-19 → 6.25 in; R-21 → 5.5 in; R-30 → 9.5 in; R-38 → 12 in.
- The default price of $55 per bag is a national planning range checked November 2026, not a quote; actual cost depends on the price you enter.
- Recommended R-value ranges (attics R-30–R-60, walls R-13–R-21, floors R-13–R-30) follow US DOE guidance by climate zone; local code sets the enforceable minimum.
Sources
- Owens Corning — publishes insulation product coverage charts for batts and loose fill — owenscorning.com
- CertainTeed — manufacturer insulation coverage and installation guides — certainteed.com
- US Department of Energy — recommended insulation R-values by climate zone — energy.gov
- The Home Depot — current retail bag pricing for fiberglass insulation batts — homedepot.com
Last reviewed: November 20, 2026, by the YardMath Editorial Team. Formulas re-checked against manufacturer datasheets; national price ranges refreshed quarterly.